The DC high voltage tester recommended internationally is characterized by advanced design, new construction, steady voltage output, high sensitivity, adaptability, easy operation, versatile mounting, safety and reliability. It may be used for on-line testing in combination with a pair twister or an extruder as well as for intermediate testing and testing for finished products.
The ST-15D compact integrated tester of which the probe ,console display and support make one block, features compact size and easy mounting. It is used mainly for on-line testing in an extruding line with non-centralized control and in combination with a pair twister.
Technical Parameters
Type
ST-15D
Voltage output
DC 0-15000V
Effective test voltage
DC 500-15000V
AC pulse ratio
<5%
Voltage stability
Power supply voltage fluctuation ± 15%, output voltage remains unchanged
Breakdown sensitivity
<600µA
Steady-state short circuit current
3-4 mA
Max. frequency of breakdown counting
10 times/s
Max. diameter of the tested wire
10mm
Max. moving speed of the tested wire
2800 meters/minute
Operational conditions
line voltage: AC220V±15%
Power frequency: 50±2Hz
Power input: 50VA
Ambient temperatures: -10~45℃
Relative humidity<85% (without condensed water)
Breakdown signal
Mode of operation:Continuous
Auto mode:Audio/visual alarm and breakdown counting
Manual mode:Audio/visual alarm, breakdown counting and control signal output
Safety interlock
In order to ensure safety for operators, the probe is provided with an interlock switch and a discharge rod.
When the front hood is opened, the high voltage is cut off first, then the discharge rod touches the electrode section to discharge the remaining electricity.